Teleconsult International Pte Ltd ICT and Telecomunication Consultancy
Teleconsult Consulting Specifications and Standards

Specifications and Standards

The following is a list of Specifications for works and materials, which are currently available:

· FDFJ1 Specification for jumpering on Fibre Distribution Frames (FDFs), using Lucent LGX distribution system
· ICCO1 Specification for the installation of Telecommunications and Data Cabling in Central Offices (COs)
· MDFJ1 Specification for jumpering on Main Distribution Frames (MDFs), using KRONE LSA PLUS termination system
· MDFJ2 Specification for jumpering on Main Distribution Frames (MDFs), using KRONE HI-BAND termination system
· OHSS1 Specification for Personal Protection Equipments (PPE)
· OHSS2 Specification for the care and use of Personal Protection Equipments (PPE)
· SBFS1 Specification for Smoke Breaks and Fire Stopping of holes through walls, floors, ceilings and plenums
· SGM1 Specification for the supply of Guyed Masts
· SST1 Specification for the supply of Self-Supporting Radio Towers
· TFFSS1 Specification for FM-200 Total Flooding Fire Suppression System
· UCSFB1 Specification for the installation of fibre optic cable in sub-duct (inner duct) using compressed air cablejet blowing technique
· UCSFC1 Specification for ribbon type non-metallic fibre optic cable, suitable for installation in High Density Polyethylene (HDPE) sub-duct
· UCSFC2 Specification for concentric loose tube type non-metallic fibre optic cable, suitable for installation in High Density Polyethylene (HDPE) sub-duct
· UCSFC3 Specification for single-mode 288 fibre ribbon type slotted core non-metallic fibre optic cable, suitable for installation in High Density Polyethylene (HDPE) sub-duct
· USCFJ1 Specification for splicing and termination of fibre optic cable
· UCSFT1 Specification for testing of fibre optic cable and installed fibre optic cable systems
· UCSHD1 Specification for High Density Polyethylene (HDPE) sub-ducts, suitable for fibre optic cable installation
· UCSHD2 Specification for installation of High Density Polyethylene (HDPE) sub-ducts in unplasticised Polyvinyl Chloride (uPVC) ducts
· UCSHW1 Specification for the installation of fibre optic cable in sub-duct (inner duct) using hand pulling and winching
· UCSPD1 Specification for 110 mm unplasticised Polyvinyl Chloride (uPVC) duct for installation underground to accommodate telecommunications cables
· UCSPD2 Specification for 155 mm unplasticised Polyvinyl Chloride (uPVC) duct for installation underground to accommodate telecommunications cables
· TTFS2 Specification for Inergen Total Flooding Fire Suppression System
· TTFS3 Specification for CO2 Total Flooding Fire Suppression System
· VESDA Specification for Very Early Smoke Detection and Alarm (VESDA) System
· WSFS Specification for Water Sprinkler Fire System
· RFIDC Specification for Raised Flooring in Data Centres,TeleHouses, TeleHotels and other ICT facilities
· PACS Specification for Precision AirConditioning System (PACS) in Data Centres
· UPS Specification for Uninterruptible Power Supply (UPS) for Data Centres
· ALIDC Specification for Aisle Lighting in Data Centres
· CCTV Specification for CCTV Surveillance System for Data Centres
· DACS1 Specification for Door Access Control System (Card Reader)
· DACS2 Specification for Door Access Control System (Biometric Reader)
· ELDC Specification for Emergency Lighting in Data Centres
· SIGNS Specification for Signs in Data Centres
· HHFE1 Specification for Hand Held Fire Extinguishers (Carbon Dioxide)
· HHFE2 Specification for Hand Held Fire Detection System (Halotron)
· SCBA Specification for Self-Contained Breathing Apparatus (SCBAs)
· LVPDC Specification for LV Power Distribution Cabling in Data Centres
· CRSDC Specification for Cabinet Racking Systems in Data Centres
· DCDC Specification for Data Cabling in Data Centres
· CEDC Specification for Clean Earth for Data Centres, bonding and grounding
· DEDC Specification for Dirty Earth for Data Centres, bonding and grounding
· DC1 Specification for Data Centre Complete (Physical attributes)
· MEME Specification for 'Meet-Me' Room
· STRM Specification for 'Staging Room'

The following is a list of Standards, which are currently available:

· OHSST Safety manual
· OHSST1 Standard for Radio Frequency (RF), non-ionising radiation safety and calculation of minimum safe distance, cellular mobile radio systems
· OHSST2 Occupational Health and Safety (OHS) standard for working in close proximity to Infra-Red (IR) radio systems


The above documents are available upon request at a fee and can be customised to meet your specific requirements.

To order, or to get more information, please contact us.